MPN 43420
Cikkszám 43420M
EAN / UPC 5703431434202
OEM TCF-142-S-SC
Készlet szint
RS-232/422/485 to optical fiber media converters
The TCF-142 media converter is equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi-mode or single-mode fiber. TCF-142 converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142 can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.
Ring and point-to-point transmission
Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF-142-S) or 5 km with multi-mode (TCF-142-M)
Decreases signal interference
Protects against electrical interference and chemical corrosion
Supports baudrates up to 921.6 kbps
Wide-temperature models available for -40 to 75°C environments
EN, FCC
UL/CUL, TUV
Yes
5 - 95 %
0 - 60 °C
-40 - 85 °C
15,4 cm
0,286 kg
7,5 cm
21,3 cm
12 - 48 V
140 mA
0,18599999999999997 kg
921,6 Kbit/s
15 kV
SC
RS-232/422/485
Fiber (SC)
Yes
GND/Rx/Tx
RxD-/RxD+/SGND/TxD-/TxD+
Data-/Data+/RxD-/RxD+/SGND/TxD-/TxD+
-25 dB
2 kV
40 km
-5 dB
1310 nm
5 Év(ek)
67 x 100 x 22 mm
RS-232/422/485 to optical fiber media converters
The TCF-142 media converter is equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi-mode or single-mode fiber. TCF-142 converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142 can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.
Automatic Baudrate Detection
The TCF-142 can automatically detect the serial baudrate. This is an extremely convenient feature. Even if a device’s baudrate is changed, the signal will still be transmitted through the media converter without any data loss.
Ring Operation
The TCF-142 can be used to connect serial devices to a fiber ring. To form the ring, connect the Tx port of one TCF-142 to the Rx port of a neighboring converter. Once the ring is set up, simply use the DIP switches to configure the TCF-142 converters for “ring mode.” When one node transmits a signal, the signal travels around the ring until it returns back to the transmitting unit, which then blocks the signal. With the TCF-142, you can set up fiber rings that have a total circumference of up to 100 km.
Automatic Data Direction Control (ADDC®)
ADDC® is a patented hardware data flow solution developed by Moxa to handle RS-485 data direction control. ADDC® senses and controls RS-485 data direction automatically, making it unnecessary to use the hand shaking signal.
Features:
“Ring” and “Point-to-Point” transmission.
Extends RS-232/422/485 transmission up to:
- 40 km with single-mode—TCF-142-S;
- 5 km with multi-mode—TCF-142-M.
Compact size.
Decreases signal interference.
Protects against electrical interference and chemical corrosion.
Supports baudrates of 50 bps to 921.6 Kbps.
Wide temperature models available (-40 to 75°C).
*A fenti termékadatokat az Icecat szolgáltatja. Az EET nem tehető felelőssé az ezzel kapcsolatos hibákért.