APC Uninterruptible Power Supply (Ups) Double-Conversion (Online) 10 Kva 10000 W

APC Uninterruptible Power Supply (Ups) Double-Conversion (Online) 10 Kva 10000 W

MPN SRV10KI

Articol nr. W128274745

Starea stocului

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

EPO
Attach the device to an Emergency Power Off (...

Citiți descrierea completă

    Specificații pentru SRV10KI

    Battery

    Battery technology

    Sealed Lead Acid (VRLA)

    Design

    Certification

    CE, IEC 62040-1-1, IEC 62040-1-2, REACH

    Display type

    LCD

    Form factor

    Tower

    Product colour

    Black

    Features

    Audible alarm modes

    Alarm when on battery/Low battery alarm/Overload alarm

    Audible alarm(s)

    Yes

    Crest factor

    3:1

    Emergency Power Off (EPO)

    Yes

    Input frequency

    40 - 70 Hz

    Input operation voltage (max)

    240 V

    Input operation voltage (min)

    220 V

    Output operation voltage (max)

    240 V

    Output operation voltage (min)

    220 V

    Output power

    10000 Watt

    Output power capacity

    10 kVA

    Surge energy rating

    600 J

    UPS topology

    Double-conversion (Online)

    Waveform

    Sine

    Logistics data

    Harmonized System (HS) code

    85078000

    Operational conditions

    Non-operating altitude

    0 - 14763.6 m

    Operating altitude

    0 - 3000 m

    Operating relative humidity (H-H)

    0 - 95 %

    Operating temperature (T-T)

    0 - 40 °C

    Storage relative humidity (H-H)

    0 - 95 %

    Other features

    Output voltage

    230 V

    Package dimensions

    Depth (package,cm)

    58 cm

    Gross Weight (Package, kg)

    84,5 kg

    Height (package,cm)

    91 cm

    Width (package,cm)

    32 cm

    Packaging data

    Cables included

    USB cable

    Manual

    Yes

    Software CD

    Yes

    Product dimensions

    Net Weight (Product, kg)

    65 kg

    Product Depth

    44,7 cm

    Product Height

    68,5 cm

    Product Width

    19 cm

    Technical details

    Sustainability certificates

    RoHS

    Vendor information

    Brand Name

    Warranty

    1 An(i)

    Descriere

    Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.

    Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.

    ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

    EPO
    Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emergency situation.

    Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.

    Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.

    LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.

    Serial connectivity
    Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.

    USB connectivity
    Provides management of the UPS via a USB port (not available on all models).

    Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.

    SmartSlot
    Customize UPS capabilities with management cards.

    LCD graphics display
    Text and mimic diagrams that display modes of operation, system parameters and alarms.

    Network manageable
    Provides remote power management of the UPS over the network.

    LED Indicators
    Provide easy-to-read status of the unit and utility power conditions.

    Serial connectivity
    Provides management of the UPS via a serial port.

    Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Audible alarms
    Provides notification of changing utility power and UPS power conditions

    Predicitive failure notification
    Provides early-warning fault analysis ensuring proactive component replacement.

    Disconnected battery notification
    Warns when a battery is not available to provide backup power.

    Double conversion on-line topology
    Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.

    ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

    Management Software
    Allows you to easily monitor your utility power and manage your UPS.

    SmartSlot
    Customize UPS capabilities with management cards.

    Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.

    Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.

    Wide input voltage range
    Designed for harsh electrical environments to save battery life.

    Intuitive LCD interface
    Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

    High efficiency
    High efficiency rates that remain stable even at lower operating power levels

    USB connection
    Use your PC to access additional power protection and management features for your UPS via a USB Port.

    Allows the user to manage the UPS functions, schedule automatic shutdown and monitor the power grid occurrences through an interactive interface that ensures an easy and intuitive monitoring.
    Management Software

    Pure sine wave output on battery
    Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

    Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.