MPN SMX750INC
Articol nr. W128260447
Starea stocului
Cold-start capable
Provides temporary battery power when the utility power is out.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utlility costs, generates l...
Yes
5 An(i)
3 Hour
Sealed Lead Acid (VRLA)
Yes
Yes
CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, VDE, REACH
LED
Rackmount/Tower
Yes
Black
2U
Alarm when on battery, Low battery alarm, Overload alarm
Yes
Yes
Yes
50/60 Hz
302 V
151 V
40 dB
50/60 Hz
240 V
220 V
600 Watt
0,75 kVA
645 J
Yes
Yes
Line-Interactive
Pure sine
Yes
85078000
8 buc.
0 - 15000 m
0 - 3000 m
0 - 95 %
0 - 40 °C
0 - 95 %
-15 - 45 °C
62 cm
29,9 kg
24,6 cm
58,9 cm
RS-232, USB cable
Yes
Yes
Yes
Yes
C13 coupler, IEC Jumpers
10 ieșire(i) AC
10/100Base-T
1
C14 coupler
Yes
RJ-45
1
Yes
1
Yes
23 kg
49 cm
8,9 cm
43,2 cm
1 An(i)
Cold-start capable
Provides temporary battery power when the utility power is out.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utlility costs, generates less heat.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Preinstalled network management card
Provides for remote management and control of the UPS over a network out of the box.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
SmartSlot
Customize UPS capabilities with management cards.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
*Datele despre produsul de mai sus sunt furnizate de Icecat. EET nu poate fi făcut responsabil pentru erori în legătură cu aceasta.