APC Uninterruptible Power Supply (Ups) 100 Kva 100000 W

APC Uninterruptible Power Supply (Ups) 100 Kva 100000 W

MPN SY100K250DR-PD

Prekės nr. W128432099

Atsargų lygis

InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.

Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Modular design
Increases adaptability with an open architecture configurable to any IT environment.

Modular design
Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.

Dual mains input
In...

Perskaitykite pilną aprašymą

    Specifikacijos SY100K250DR-PD

    Battery

    Battery recharge time

    3,5 Hour

    Hot-swap battery

    Yes

    Design

    Certification

    cUL Listed,CE,EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC Part 15 Class A,UL Listed,VFI-SS-111

    Product colour

    Black

    Features

    Emergency Power Off (EPO)

    Yes

    Input frequency

    40/70 Hz

    Output power

    100000 Watt

    Output power capacity

    100 kVA

    Operational conditions

    Operating relative humidity (H-H)

    0 - 95 %

    Operating temperature (T-T)

    0 - 40 °C

    Storage relative humidity (H-H)

    0 - 95 %

    Storage temperature (T-T)

    -15 - 40 °C

    Other features

    Battery type

    VRLA

    Dimensions (WxDxH)

    2350 x 1070 x 1991 mm

    Input connection type

    Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)

    Interface

    Smart-Slot

    Output connections

    1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G)

    Package dimensions (WxDxH)

    2990 x 1270 x 2150 mm

    Package dimensions

    Gross Weight (Package, kg)

    5,2 kg

    Product dimensions

    Net Weight (Product, kg)

    4 kg

    Vendor information

    Brand Name

    Warranty

    1 Metai

    Aprašymas

    InfraStruXure Central compatible
    Enables centralized management via APC InfraStruXure® Central.

    Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance

    Modular design
    Increases adaptability with an open architecture configurable to any IT environment.

    Modular design
    Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.

    Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.

    SmartSlot
    Customize UPS capabilities with management cards.

    Hot-swappable intelligence modules
    Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

    Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

    Configurable for N+1 internal redundancy
    Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

    Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Battery modules connected in parallel
    Delivers higher availability through redundant batteries.

    Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.

    *Aukščiau pateiktus gaminio duomenis pateikia „Icecat“. EET negali būti atsakinga už klaidas, susijusias su tuo.

    EET LietuvaBregnerødvej 133 D3460 BirkerødPVM nr. 35239480
    Lietuva / Lietuvių