MPN SUVTP15KH2B2S
EAN / UPC 5415247021568
Niveau de stock
APC Smart-UPS VT, 12 kW / 15 kVA,Input 400V 3PH / Output 230V, 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model.
Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Smart UPS signalling RS-232 cable, Start up included, User Manual.
Availability
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Scalable r...
VRLA
356 x 812 x 1499 mm
DB-9 RS-232, Smart-Slot
400 V
(1) Hard Wire 4-wire (3PH + G) (1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals
650 x 1062 x 1643 mm
Hard Wire 5-wire (3PH + N + G)
5 Hour
2
Sealed Lead Acid (VRLA)
Oui
40/70 Hz
21 A
64 dB
12000 Watt
15 kVA
0 - 95 %
0 - 15000 m
0 - 999.9 m
0 - 95 %
0 - 40 °C
-15 - 45 °C
C-tick,CE,EN 50091-2,EN/IEC 62040-3,IEC 61000-3-2, IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-112
Noir
85078000
85078000
591,2 kg
591,1 kg
APC Smart-UPS VT, 12 kW / 15 kVA,Input 400V 3PH / Output 230V, 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model.
Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Smart UPS signalling RS-232 cable, Start up included, User Manual.
Availability
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Scalable runtime
Allows additional run time to be quickly added as needed.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
- Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Serviceability
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Battery replacement without tools
Allows quick, easy battery replacement.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.
- Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Manageability
- Network manageable
Provides remote management of the UPS over the network.
- InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
- LCD display
Alpha-Numeric Display which displays system parameters and alarms.
- Audible alarms
Provides notification of changing utility power and UPS conditions.
- Programmable frequency
Ensures compatibility with different input frequencies.
- LED status indicators
Quickly understand unit and power status with visual indicators.
- SmartSlot
Customize UPS capabilities with management cards.
Total Cost of Ownership
- Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
- Manual maintenance bypass
Reduces installation costs by eliminating the need for an external mechanical bypass.
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Protection
- Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
- Cold-start capable
Provides temporary battery power when the utility power is out.
*Les données produit ci-dessus sont fournies par Icecat. A cet égard, EET ne peut être tenu responsable des erreurs.