APC MGE Galaxy 3500 10kVA 400V with 2 Battery Modules Expandable to 4, Start-up 5X8

APC MGE Galaxy 3500 10kVA 400V with 2 Battery Modules Expandable to 4, Start-up 5X8

MPN G35T10KH2B4S

EAN / UPC 731304274940

Niveau de stock

APC MGE Galaxy 3500, 8000 Watts / 10 kVA,Input 400V 3PH / Output 400V 3PH, Extended runtime model.

Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Smart UPS signalling RS-232 cable, Start-Up Service, User Manual.

Availability
- Dual mains input: Increases availability by allowing the UPS to be connected to two separate
power sources
- Scalable runtime: Allows a...

Lire la description complète

    Caractéristiques G35T10KH2B4S

    Autres caractéristiques

    Connexions de sortie

    1 x 4-wire (3PH + G) 1 x 5-wire (3PH + N + G) 1 x Screw Terminals

    Dimensions (LxPxH)

    523 x 838 x 1491 mm

    Dimensions du colis (LxPxH)

    650 x 1062 x 1643 mm

    Note relative à la tension-rendement

    +/- 5%

    Type de batterie

    VRLA

    Type de connexion d'entrée

    5-wire (3PH + N + G)

    Batterie

    Technologie batterie

    Sealed Lead Acid (VRLA)

    Temps de rechargement de la batterie

    5 Hour

    Caractéristiques

    Bouton de coupure d'urgence d'alimentation (EPO)

    Y/Yes

    capacité de la puissance de sortie

    10 kVA

    Fréquence d'entrée

    40/70 Hz

    Intensité (max.)

    14 A

    Niveau sonore

    43,3 dB

    Puissance de sortie

    8000 Watt

    Conditions environnementales

    Altitude de fonctionnement

    0 - 999.9 m

    Altitude de non fonctionnement

    0 - 15000 m

    Humidité relative de fonctionnement (H-H)

    0 - 95 %

    Taux d'humidité relative (stockage)

    0 - 95 %

    Température d'opération

    0 - 40 °C

    Température hors fonctionnement

    -15 - 45 °C

    Design

    Certification

    CE,EN 50091-2,EN/IEC 62040-3,EN/IEC 62040-1-1,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-111

    Couleur du produit

    Black

    Voyants

    Y/Yes

    Détails techniques

    Code du système harmonisé

    85078000

    Données logistiques

    Code du système harmonisé

    85078000

    Package dimensions

    Depth (package,cm)

    183 cm

    Gross Weight (Package, kg)

    474 kg

    Height (package,cm)

    100 cm

    Width (package,cm)

    120 cm

    Product dimensions

    Net Weight (Product, kg)

    0,99 kg

    Vendor information

    Brand Name

    Warranty

    1 Année (s)

    Description

    MGE Galaxy 3500 10kVA 400V with 2 Battery Modules Expandable to 4, Start-up 5X8

    APC MGE Galaxy 3500, 8000 Watts / 10 kVA,Input 400V 3PH / Output 400V 3PH, Extended runtime model.

    Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Smart UPS signalling RS-232 cable, Start-Up Service, User Manual.

    Availability
    - Dual mains input: Increases availability by allowing the UPS to be connected to two separate
    power sources
    - Scalable runtime: Allows additional runtime to be quickly added as needed
    - Hot-swappable batteries: Ensure clean, uninterrupted power to protected equipment while
    batteries are being replaced
    - Generator compatible: Ensure clean, uninterrupted power to protected equipment when generator power is used
    - Automatic internal static bypass: Supplies utility power to the connected loads in the event of a
    UPS overload condition or fault
    - Battery modules connected in parallel: Delivers higher availability through redundant batteries

    Serviceability
    - Batteries that can be replaced by qualified personnel: Increases availability by allowing qualified
    personnel to perform upgrades and replacement of the batteries reducing the Mean Time To
    Repair (MTTR)
    - Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced
    - Shippable with modules installed: Enables pre-installation UPS staging and testing and faster
    installation
    - Modular design: Provides fast serviceability and reduced maintenance requirements via selfdiagnosing, field-replaceable modules

    Manageability
    - Network manageable: Provides remote management of the UPS over the network
    - InfraStruXure Central Compatible: Enables centralized management via InfraStruXure Central
    - LCD: Alphanumeric display which displays system parameters and alarms
    - Audible alarms: Provides notification of changing utility power and UPS conditions
    - Programmable frequency: Ensures compatibility with different input frequencies
    - LED status indicators: Quickly understand unit and power status with visual indicators
    - SmartSlot: Customize UPS capabilities with managements cards

    Total Cost of Ownership
    - Input power factor correction: Minimizes installation costs by enabling the use of smaller
    generators and cabling
    - Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature
    - Manual maintenance bypass: Reduces installation costs by eliminating the need for an external
    mechanical bypass
    - Intelligent battery management: Maximizes battery performance, life, and reliability through
    intelligent, precision charging

    Protection
    - Frequency and voltage regulation: Gives higher application availability by correcting poor
    frequency and voltage conditions without using the battery
    - Safety-agency approved: Ensures the product has been tested and approved to work safely with
    the connected service provider equipment and within the specified environment. UL, FCC, CE,
    C-Tick approvals
    - Cold-start capable: Provides temporary battery power when the utility power is out

    *Les données produit ci-dessus sont fournies par Icecat. A cet égard, EET ne peut être tenu responsable des erreurs.

    EET France38 rue Mozart92110 ClichyNuméro de TVA 82 430 022 913
    France / Français