Aten 30-Outlet 0U 3-Phase Intelligent PDU with Cascading (32A) (24x C13, 6x C19)

Aten 30-Outlet 0U 3-Phase Intelligent PDU with Cascading (32A) (24x C13, 6x C19)

MPN PG98330G-AT

Número de Artículo W127154297

Nivel de existencias

When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the...

Leer descripción completa
  • ARM Cortex-A8 processor for flexible control methods via LAN / COM / USB / environmental sensor ports and enhanced monitoring via LCD console

  • Allows for connecting up to 64 PDU units with cascading

  • Energy-efficient relays allow operators to control a large amount of current flow for lower energy consumption

  • Precise kWh metering (+/-1% ) for better power consumption habits, baselines, and initiative tracking

Especificaciones de PG98330G-AT

Design

Capacidad rack

0U

Color producto

Black

Display

LCD

Montaje en rack

Yes

Tipo

Three-phase

Tipos de PDU

Metered/Switched

Features

Algoritmos de seguridad

SMTP-AUTH/TLS

Botón Reset

Yes

Certificación

EMC

Encadenamiento

Yes

Longitud del cable

3 m

Protección con contraseña

Yes

Logistics data

Altura de la caja maestra (exterior)

17,9 cm

Ancho de la caja maestra (exterior)

22,9 cm

Longitud de la caja maestra (externa)

194,5 cm

Peso bruto de la caja maestra (externa)

11,23 kg

Peso neto de la caja maestra (externa)

11,23 kg

Volumen de caja maestra (externoa)

79853,5 cm³

Management features

Firmware actualizable

Yes

Firmware actualizable vía

Network

Monitorización

Current/Power/Voltage

Protocolos de red soportados

/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n, IPv6, SMS

Operational conditions

Humedad relativa de funcionamiento (H-H)

0 - 80 %

Temperatura de almacenamiento (T-T)

-20 - 60 °C

Temperatura de funcionamiento (T-T)

0 - 60 °C

Package dimensions

Depth (package,cm)

194,5 cm

Gross Weight (Package, kg)

1,49 kg

Height (package,cm)

17,9 cm

Width (package,cm)

22,9 cm

Packaging content

Kit de montaje en rack

Yes

Manual

Yes

Packaging data

Volumen de paquetes

79853,5 cm³

Ports & interfaces

Enchufe de alimentación

IEC309

Puertos LAN Ethernet (RJ-45)

2

Puertos serie

2

Puertos USB

1

Salidas AC

30 salidas AC

Tipos de salidas AC

C13 coupler/C19 coupler

Power

Capacidad de carga

22170 VA

Corriente máxima

32 A

Disyuntor

Yes

Frecuencia de entrada AC

50 - 60 Hz

Tensión de entrada nominal

230 - 400 V

Tensión de salida nominal

230 V

Product dimensions

Net Weight (Product, kg)

1,29 kg

Product Depth

179 cm

Product Height

6,8 cm

Product Width

5,6 cm

Technical details

Certificados de sostenibilidad

CE

Conformidad sostenibilidad

Yes

Vendor information

Brand Name

Warranty

2 Año/s

Descripción

When maintaining operating uptime in a data center or server room, sustainable energy efficiency can make all the difference. The implementation of effective power management often involves improvements at both the hardware and software level. As the trend for 3-phase power grows due to its efficiency to generate, transfer, and distribute electricity, ATEN is introducing its latest PG series of PDUs, available in IEC socket configuration, that are designed with 0U rack housing to accommodate the increasing demand for power to high-density IT equipment in server rooms and data centers. Each PG98330 PDU, utilizing an ARM-Cortex A8 processor, is equipped with 30 port outlets capable of running at higher voltages, powers up all connected equipment in less than 10 seconds once plugged in, and delivers the most accurate kWh energy usage data (+/-1%) for better power consumption habits, baselines, and initiative tracking. With energy saving in mind, the PG98330 is purposed to enable lower energy consumption for best practice in a network infrastructure, while promoting up to 70.65 kg (131.4 kw equivalent of power consumption) of reduced CO2 emission, reduced electricity expenses, and lower carbon taxes to pay each year.

Energy-Saving Relay
Thanks to the built-in energy-saving relays – a subtype of electromagnetic switch – controlling a large amount of current flow becomes easy, which results in annual saving of 131.4 kW power consumption per 30-outlet PDU unit, compared with models without energy-saving relays. In addition, power distribution will remain functional and uninterrupted even when a failure occurs, enabling superior uptime to optimize system reliability.

Hydraulic-Magnetic Circuit Breaker
With the built-in hydraulic-magnetic circuit breaker in place, electricity supply can be automatically switched off to protect connected devices from getting overloaded or damaged, while maintaining stable power distribution.

Secure Locking Enhancement
The outlets can be protected with a secure lock to prevent power cords from becoming unplugged due to vibration or human errors.

Real-time Alerts via LCD Display
The illuminated LCD display can display warnings to alert users of unusual power states.

Hot-Swappable Function
The LCD console panel is hot-swappable and can be removed, replaced, or repaired without powering down a mission-critical connected load.

Dual LAN Ports for Scalable Network Setup
The PG98330 is equipped with dual LAN ports (e.g. Internet and Intranet) supporting up to 1G Ethernet connection, and can be cascaded to connect up to 64 PDUs, saving expense on installing extra network switches to incorporate network connections while sparing more rack space to accommodate more IT equipment in an expandable network.

Environment Sensors
The Sensor port enables RJ-45 connectivity to connect or daisy-chain up to 8 environment sensors for monitoring and management of temperature, humidity, airflow, differential air pressure, and leaks, featuring alerts for potential threats.

Flexible On-Site Network Operation
For quick operation, connecting a serial device to the PDU with its COM port provides another means to undertake communication via CLI commands. In addition, the same port is also functional as a PON port, available for Ethernet connection to a KN series KVM over IP Switch to centralize power management of up to 16 daisy-chained PDUs.

Networkable via WiFi
The PG98330 can be networked via connection to a USB WiFi dongle to perform DCIM, firmware upgrade, log export, quick configuration, and more.

Adjustable Power Cord for Flexible In-Rack Installation
The PG98330 comes with an adjustable power cord built in to the unit capable of 90-degree rotation to allow flexible in-rack installation, resulting in better cable organization.

DCIM Monitoring
Integrated with ATEN’s eco DC – a PC- and web-based tool for optimized Data Center Infrastructure Management (DCIM) – power distribution, energy, and environmental data from PDUs and connected devices can be monitored via a friendly web GUI for smart power management.

Colored Panel for Smarter Power Monitoring
The PG series PDUs feature a LCD console panel in default red and can be re-colored with options of yellow, purple, blue, and green through optional purchase of colored stickers. These color codes make it easier to differentiate between power feed settings and also speed up troubleshooting in case of unexpected failures.