APC Rack PDU, Switched, 2U, 32A, 230V, 16x IEC 320 C13, 445 x 114 x 89 mm

APC Rack PDU, Switched, 2U, 32A, 230V, 16x IEC 320 C13, 445 x 114 x 89 mm

MPN AP7922B

EAN / UPC 0731304331636

Nivel de existencias

Availability

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresho...

Leer descripción completa

    Especificaciones de AP7922B

    Design

    Capacidad rack

    2U

    Color producto

    Black

    Soporte

    Horizontal

    Tipo

    Single-phase

    Tipos de PDU

    Metered, Switched

    Features

    Certificación

    CE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH

    Conformidad RoHS

    Yes

    Longitud del cable

    3,05 m

    Management features

    Control de salida

    Lock-out, Recycle, Turn off, Turn on

    Monitorización

    Current, Power, Voltage

    Operational conditions

    Altitud de funcionamiento

    0 - 3000 m

    Altitud no operativa

    0 - 15000 m

    Humedad relativa de almacenamiento (H-H)

    0 - 95 %

    Humedad relativa de funcionamiento (H-H)

    0 - 95 %

    Temperatura de almacenamiento (T-T)

    -25 - 65 °C

    Temperatura de funcionamiento (T-T)

    0 - 45 °C

    Package dimensions

    Depth (package,cm)

    52 cm

    Gross Weight (Package, kg)

    6,96 kg

    Height (package,cm)

    15 cm

    Width (package,cm)

    37 cm

    Packaging content

    Contenido del paquete

    Documentation CD, Installation Guide, Rack Mounting Brackets

    Packaging data

    Dimensiones del paquete (AnxPxAl)

    508 x 368 x 140 mm

    Ports & interfaces

    Enchufe de alimentación

    IEC309

    Salidas AC

    16 salidas AC

    Tipos de salidas AC

    C13 coupler

    Power

    Capacidad de carga

    7360 VA

    Corriente máxima

    32 A

    Frecuencia de entrada AC

    50 - 60 Hz

    Máxima corriente de entrada por fase

    32 A

    Máximo consumo total de corriente por fase

    32 A

    Potencia máxima

    7360 Watt

    Tensión de entrada nominal

    200-230 V

    Tensión de salida nominal

    230 V

    Product dimensions

    Net Weight (Product, kg)

    6,9 kg

    Technical details

    Certificados de sostenibilidad

    RoHS

    Vendor information

    Brand Name

    Warranty

    1 Año/s

    Weight & dimensions

    Dimensiones (AnxPxAl)

    445 x 114 x 89 mm

    Descripción

    Rack PDU, Switched, 2U, 32A, 230V, 16x IEC 320 C13, 445 x 114 x 89 mm

    Availability

    Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

    Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

    Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

    Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

    Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

    Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

    Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

    Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

    Marketing Features

    Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

    Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

    Remote Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

    Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

    Local Current Monitoring Display
    The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

    Agility

    Single input power source
    Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

    Wide range of input and output connections
    Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

    Rack-Mountable
    Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

    *Los datos de producto anteriores son proporcionados por Icecat. EET no se hace responsable de los errores en relación con esto.