MPN SMX2200RMHV2U
EAN/UPC 731304272687
Stock level
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by...
Yes
702 VAh
5 year(s)
3 Hour
Sealed Lead Acid (VRLA)
Yes
9.8 min
25.3 min
1.83 m
CE, CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, FCC Part 15 Class A, IEC 60950, IRAM, RCM, UL 1778, VDE, REACH, PEP, EOLI
Rackmount/Tower
Battery replacement
Black
2U
Yes
Yes
Yes
Yes
98.1 %
Yes
10 Millisecond
2 Millisecond
50/60 Hz
55 dB
50/60 Hz
240 V
208 V
1980 Watt
2.2 kVA
4 Millisecond
645 J
Yes
Line-Interactive
Sine
85078000
8 pc(s)
0 - 15000 m
0 - 3000 m
0 - 95 %
0 - 40 °C
0 - 95 %
-15 - 45 °C
230 V
230 V
87.5 cm
48.14 kg
25 cm
60 cm
RS-232, USB cable
Yes
Yes
Yes
C13 coupler, C19 coupler
9 AC outlet(s)
2
C20 coupler
Yes
Yes
48 kg
66.7 cm
8.5 cm
43.2 cm
85078000
Green Premium, RoHS
1 Year(s)
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
*The product data above is provided by Icecat. EET cannot be held responsible for errors in relation to this.