APC 520W, 850VA, 230V, 47/63 Hz, 1x USB

APC 520W, 850VA, 230V, 47/63 Hz, 1x USB

MPN BE850G2-UK

EAN / UPC 731304347323

Nivel de existencias

Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms
Provides notification of changing utility power and UPS power conditions

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery charging indicator
Lets you know when your battery is charging and when it is ful...

Leer descripción completa

    Especificaciones de BE850G2-UK

    Battery

    Arranque en frío

    Yes

    Duración de la batería (máx.)

    5 año(s)

    Intercambio de baterías en caliente

    Yes

    Prueba automática de la batería

    Yes

    Tiempo de recarga de la batería

    16 Hour

    Design

    Certificación

    CE, EAC

    Color producto

    Black

    Conformidad RoHS

    Yes

    Factor forma

    Compact

    Indicadores LED

    Y/Yes

    Longitud cable

    1,83 m

    Features

    Alarmas(es) sonora(s)

    Yes

    Calificación energética de sobretensión

    310 J

    Capacidad de potencia de salida

    0,85 kVA

    Características de sobretensión

    Digital Subscriber Line (DSL)

    Corriente máxima

    6 A

    Eficacia

    80 %

    Frecuencia de entrada

    47/63 Hz

    Frecuencia de salida

    50/60 Hz

    Modos de alarma audible

    Alarm when on battery/Overload alarm

    Nivel sonoro

    45 dB

    Onda

    Sine

    Potencia de salida

    520 Watt

    Protección de sobretensión

    Yes

    Topología UPS

    Standby (Offline)

    Voltaje de funcionamiento de entrada (máx.)

    266 V

    Voltaje de funcionamiento de entrada (mín.)

    180 V

    Voltaje de funcionamiento de salida (máx.)

    230 V

    Voltaje de funcionamiento de salida (mín.)

    220 V

    Logistics data

    Código del Sistema Armonizado (SA)

    85078000

    Peso bruto de la caja maestra (externa)

    16 kg

    Operational conditions

    Altitud no operativa

    0 - 4500 m

    Humedad relativa de almacenamiento (H-H)

    0 - 95 %

    Humedad relativa de funcionamiento (H-H)

    0 - 90 %

    Temperatura de almacenamiento (T-T)

    -15 - 45 °C

    Temperatura de funcionamiento (T-T)

    0 - 40 °C

    Package dimensions

    Depth (package,cm)

    36,5 cm

    Gross Weight (Package, kg)

    4,5 kg

    Height (package,cm)

    12 cm

    Width (package,cm)

    13 cm

    Packaging data

    Manual

    Yes

    Ports & interfaces

    Puerto USB

    Yes

    Puertos LAN Ethernet (RJ-45)

    1

    Tipo puerto USB

    USB Type-C

    Product dimensions

    Net Weight (Product, kg)

    4 kg

    Product Depth

    36,5 cm

    Product Height

    12 cm

    Product Width

    13 cm

    Technical details

    Certificados de sostenibilidad

    RoHS

    Código del Sistema Armonizado (SA)

    85078000

    Vendor information

    Brand Name

    Warranty

    1 Año/s

    Descripción

    520W, 850VA, 230V, 47/63 Hz, 1x USB

    Adjustable voltage sensitivity
    Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

    Audible alarms
    Provides notification of changing utility power and UPS power conditions

    Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.

    Battery charging indicator
    Lets you know when your battery is charging and when it is fully charged.

    Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance

    Building Wiring Fault Indicator
    This LED informs users of potentially dangerous wiring problems in the wall circuit.

    Cold-start capable
    Provides temporary battery power when the utility power is out.

    Dataline surge protection
    Provides protection of connected equipment from power surges on the data lines.

    Disconnected battery notification
    Warns when a battery is not available to provide backup power.

    Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

    Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

    Simple battery replacement
    Increases UPS availability by allowing quick, easy battery replacement.

    USB charging ports
    Simultaneously charge mobile devices, including smartphones and tablets.

    USB connection
    Use your PC to access additional power protection and management features for your UPS via a USB Port.

    User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

    *Los datos de producto anteriores son proporcionados por Icecat. EET no se hace responsable de los errores en relación con esto.

    EET EspañaCalle Aragoneses 1528108 AlcobendasCIF/NIF A81528994