Moxa Port-powered RS-232 to fiber converters

Moxa Port-powered RS-232 to fiber converters

MPN 41767

Número de Artículo 41767M

EAN / UPC 5703431417670

OEM TCF-90-S-ST

Nivel de existencias

Port-powered RS-232 to optical fiber media converters.
The TCF-90 is a compact media converter that transmits RS-232 signals over optical fiber. Power is derived from either the serial port or an external power source. The TCF-90 extends RS-232 transmission up to 5 km with multi-mode fiber, or up to 40 km with single-mode fiber. A pair of TCF-90 converters can be used to connect two RS-232 devices with optical fiber in full duplex mode. The optical fiber isolates the data signals from...

Leer descripción completa
  • Uses either external power or power over serial

  • Extends RS-232 transmission up to 40 km with single-mode (TCF-90-S) or 5 km with multi-mode (TCF-90-M)

  • Reduces signal interference

  • Protects against electrical interference and chemical corrosion

  • Compact size

Especificaciones de 41767

Certificates

Certificación

CE FCC

Operational conditions

Humedad relativa de funcionamiento (H-H)

5 - 95 %

Temperatura de almacenamiento (T-T)

-20 - 75 °C

Temperatura de funcionamiento (T-T)

0 - 60 °C

Package dimensions

Depth (package,cm)

2,2 cm

Gross Weight (Package, kg)

1 kg

Height (package,cm)

4,2 cm

Width (package,cm)

8 cm

Power

Consumo de energía

20 mA

Voltaje de entrada

12 - 48 V

Product dimensions

Net Weight (Product, kg)

0,5 kg

Technical details

Conector de fibra óptica

ST

Distancia de transmisión (monomodo)

40 km

Interfaz de salida

Fiber (ST)

Interfaz host

RS-232

Longitud de onda

1310 nm

Salida TX

-5 dB

Señales RS-232

GND, Rx, Tx

Sensibilidad RX

-24 dB

Velocidad

0,05 Kbit/s

Vendor information

Brand Name

Warranty

2 Año/s

Weight & dimensions

Dimensiones (AnxPxAl)

42 x 80 x 22 mm

Descripción

Port-powered RS-232 to fiber converters

Port-powered RS-232 to optical fiber media converters.
The TCF-90 is a compact media converter that transmits RS-232 signals over optical fiber. Power is derived from either the serial port or an external power source. The TCF-90 extends RS-232 transmission up to 5 km with multi-mode fiber, or up to 40 km with single-mode fiber. A pair of TCF-90 converters can be used to connect two RS-232 devices with optical fiber in full duplex mode. The optical fiber isolates the data signals from dangerous increases in ground potential, ground loops, and electrical EMI/RFI noise, and enhances data security by eliminating the harmful effects of RF radiation and susceptibility to electromagnetic radiation.

Self-powered RS-232 to Optical Fiber
Connecting RS-232 devices to the TCF-90 is easy. The ST-type optical fiber connector is designed especially for data communication applications that transmit data either between or within buildings. The TCF-90 can be used for industrial applications and for applications that require secure data transfer.
The RS-232 port on the TCF-90 uses a DB9 female socket to connect directly to the host PC, with power drawn from the TxD, RTS, and DTR lines. Although the TCF-90 can obtain enough power from the three data/handshake lines whether the signal is high or low, we strongly recommend setting either the RTS or DTR signal to ON.

Patented LED Port Power Indicator
It's easy enough to use a multimeter to test if the serial device is supplying the TCF-90 with enough power through the serial connection, but why bother when the TCF-90 can do the testing for you? Connect the TCF-90 to the device's RS-232 port and set the SW4 switch to Test mode. If the patented port power LED indicator lights up, the TCF-90 is receiving enough power. If the LED does NOT light up, you will need to attach an external power source to the TCF-90.

Optional External Power Source
In most circumstances, the TCF-90 should be able to operate without using an external power source. However, an external USB power cord or DC power supply can be used in situations where the handshake lines are not available, both the RTS/DTR signals are set to OFF, or the attached device's serial interface chip provides less power than required.

*Los datos de producto anteriores son proporcionados por Icecat. EET no se hace responsable de los errores en relación con esto.

EET EspañaCalle Aragoneses 1528108 AlcobendasCIF/NIF A81528994
España / Español