APC NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure with Sides Black

APC NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure with Sides Black

MPN AR3100

EAN/UPC 731304226390

Stock level

Rack enclosures with advanced cooling, power distribution, and cable management for server and networking applications in IT environments.
Adjustable mounting depth
Vertical mounting rails are adjustable for equipment with various mounting depths.
Guaranteed Compatability
Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. APC's "Fits Like a Glove" money back guarantee provides peace of mind that all of your EIA-310-D complian...

Read full description

    Specifications for AR3100

    Features

    Adjustable feet

    Yes

    Back door key lock

    Yes

    Castor wheels

    Yes

    Certification

    REACH

    Front door key lock

    Yes

    Key lock

    Yes

    Maximum weight capacity

    1701 kg

    Maximum weight capacity (rolling)

    1020.58 kg

    Product colour

    Black

    Rack capacity

    42U

    Side panel key lock

    Yes

    Side panels included

    Yes

    Type

    Freestanding rack

    Logistics data

    Harmonized System (HS) code

    85381000

    Other features

    Dimensions (WxDxH)

    600 x 1070 x 1991 mm

    Dynamic load

    1022.73 kg

    Package dimensions (WxDxH)

    899 x 1219 x 2118 mm

    Static load

    1704

    Package dimensions

    Depth (package,cm)

    110.2 cm

    Gross Weight (Package, kg)

    140 kg

    Height (package,cm)

    216 cm

    Width (package,cm)

    64.5 cm

    Product dimensions

    Net Weight (Product, kg)

    124.99999999999999 kg

    Product Depth

    107 cm

    Product Height

    199.1 cm

    Product Width

    60 cm

    Technical details

    Harmonized System (HS) code

    85381000

    Sustainability certificates

    RoHS

    Vendor information

    Brand Name

    Homepage

    http://www.apc.com/tools/ups_selector/

    Warranty

    5 Year(s)

    Weight & dimensions

    Mounting depth (max)

    91.5 cm

    Mounting depth (min)

    19.1 cm

    Size (imperial)

    19 "

    Description

    NetShelter SX 42U 600mm Wide x 1070mm Deep Enclosure with Sides Black

    Rack enclosures with advanced cooling, power distribution, and cable management for server and networking applications in IT environments.
    Adjustable mounting depth
    Vertical mounting rails are adjustable for equipment with various mounting depths.
    Guaranteed Compatability
    Vendor-neutral mounting for guaranteed compatibility with all EIA-310 compliant 19" equipment. APC's "Fits Like a Glove" money back guarantee provides peace of mind that all of your EIA-310-D compliant rack-mount equipment will physically fit in a NetShelter SX enclosure.
    Ventilated Doors with Scalable Cooling Options
    Superior door ventilation exceeds airflow requirements for major servers. Scalable cooling options for high-density applications.
    Reversible doors
    In situations where it is desirable for the front door to open from
    the opposite side, doors can be detached and reversed.
    Expansion
    SX enclosures can be easily expanded upon to create complete rows of enclosures. In addition, the SX can be tied into the existing VX build-outs via the appropriate baying hardware.
    Door ventilation exceeds 830 in2 (5355 cm2)
    Adequate ventilation is required for proper operation of today's servers. NetShelter SX Enclosures include fully perforated front and rear doors to provide ample ventilation for servers and networking equipment. The perforation pattern provides 919 square inches of open area on the front door, exceeding requirements set forth by major server manufacturers. Although this ventilation pattern provides adequate cooling for most configurations, air-moving accessories such as APC's Air Distribution Unit are also available to support higher heat density applications.
    Rear Cable Management channels
    Integrated rear cable management channels allow customers to easily route, manage, and access large numbers of data cables even while an enclosure is loaded with rack-mount equipment and bayed within a row.
    Rear Power Distribution channels
    Rear power distribution channels provide easy access to multiple receptacles occupying zero U in recessed channels . The rear power distribution channels allow APC basic, metered, and switched vertical rack PDU's to be installed easily in the rear without interfering with equipment or taking up valuable U space. This provides increased accessibility to receptacles and allows customers to support more power cords within the enclosure. Up to 42 5-15R receptacles can be installed in just one rear cabling channel.
    Cable Access
    Generous cable access holes are provided in the roof and base of the NetShelter SX to enable power and data cables to be routed into the rack either from overhead or from underneath a raised floor. The NetShelter SX enclosure offers eight cable access holes of various sizes on the roof. The eight are broken out as follows: five 60mm x 175mm, two 79mm x 167mm, and one 79mm x 245mm. In addition, for maximum cable routing capacity, the roof can be removed entirely even if cables are already installed. The base of the rack is an open design, maximizing the potential access space for under-floor cable routing.
    Numbered U positions
    Rapid installation of rack mounted equipment.
    Optimized depth
    Enclosures deeper than those traditionally used are required to properly install the latest servers, distribute power, and manage cabling in today's data centers. The struggle facing data center managers is determining how deep to go without sacrificing valuable floor space. In a hot aisle/cold aisle layout, the NetShelter SX Enclosures provide the maximum enclosure depth (42 inches (107 cm)) without sacrificing floor space. This allows for 36 inches (91 cm) of clearance in the hot aisle and 48 inches (122 cm) in the cold aisle. In a hot aisle/cold aisle layout, selecting enclosures less than 42 inches (107 cm) deep will not allow more enclosures to be installed in a data center, but only increase the clearance in the hot aisle.
    Optimized width
    NetShelter SX Enclosures are designed to align exactly on standard 24 inch and 600 mm wide floor tiles when bayed together.
    Rolls through a 2 meter doorway
    APC has made installation fast and easy by designing the SX enclosure such that it rolls through standard 2 meter doorways. This feature does not apply to the 48U versions of the SX.
    Ships fully assembled
    The NetShelter SX Enclosures ship fully assembled reducing the time required to install equipment.
    Simple Selection
    No need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. APC has made it easy by handling the details and providing complete enclosures with single part numbers.
    Lockable doors and side panels
    Increased level of security to prevent unauthorized entry. Front doors, rear doors, and side panels are lockable and only accessible with a key provided with NetShelter Enclosures.
    Structural Stability
    A proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for 3000 lb (1364 kg) static and 2250 lb (1023 kg) dynamic load ratings.
    Protective grounding provisions
    Integrated grounding provides safety protection against electric shock and improves the reduction of EMI emissions. The side panels and roof have integral grounding features which eliminates the need for ground straps or wires. The front and rear doors of the SX enclosures are supplied with factory-fitted ground wires.
    UBC Zone 4 stabilization provisions
    NetShelter SX Enclosures are UBC (Uniform Building Code) Zone 4 compliant if used in conjunction with APC's Bolt-Down Kit (part # AR7701).
    Quick release doors
    During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the enclosure doors. Quick release hinge pins allow for fast, easy access.
    Quick release side panels
    During installation and while conducting routine maintenance of installed equipment, it is often advantageous to remove the side panels. Quick release side panels allow for quick, easy access.
    Split rear doors
    Split rear doors improve access and serviceability to rear of rack mounted equipment. The split rear doors help to maximize floor space. Only 11 inches (279 mm) of clearance is required behind the enclosures to allow for door swing.

    *The product data above is provided by Icecat. EET cannot be held responsible for errors in relation to this.

    EET United Kingdom30 Riverside WayUB8 2YF UxbridgeCompany Reg No. 6353017
    United Kingdom / English